Volume 3 Issue 1
2019-07-09 Research Article
Abstract
Background: We have developed a femoral supporting pad with an integrated ultrasound probe holder and examined its practical usability on patients with lower limb surgery.
Objectives: To evaluate the function of this novel femoral supporting pad with respect to its practicability during the performance of a distal sciatic nerve blockade, the time needed to perform this blockade including the catheter insertion and the quality of postoperative analgesia within the first 24 hours.
Methods: 50 patients which had been scheduled for elective lower leg, ankle or foot surgery had received a continuous blockade of the distal sciatic nerve. Sciatic nerve blockade was performed sonographically controlled with the patients in supine position by using our novel femoral supporting pad with an integrated ultrasound probe holder.
Primary endpoint: duration of the intervention. Secondary endpoints: pain intensity (visual analogue scale VAS 0-10) at the first postoperative day; cumulative opioid (piritramide) requirement during their stay on the post Anaesthesia care unit (PACU) with vs. without distal sciatic nerve blockade.
Results: 49/50 patients received a distal sciatic catheter, which had been sonographically placed within a mean time (mean ± sd) of 11:30 ± 3:13 minutes. VAS at the first postoperative day was (mean ± sd) 1 ± 2 at rest and 2 ± 2 as maximum. The piritramide requirement during PACU stay (mean ± sd) was 11 ± 8 mg without vs. 3 ± 6 mg with distal sciatic nerve blockade (p< 0.05).
Conclusion: Continuous distal sciatic nerve blockade using a novel femoral supporting pad with an integrated ultrasound probe holder was feasible in 49 of 50 patients within 11 minutes and 30 seconds.
Abstract Read Full Article HTMLDOI: 10.29328/journal.ijcar.1001012 Cite this Article
2019-07-04 Case Report
Abstract
Provide a safety anesthesia to patient is only possible with the knowledge of material surrounding the operation room. Benzine is highly flammable substance and can produce several injures without the necessary care. This case describes a small fire caused by the presence of benzine in the surgical field concomitant with the use of electrocautery, which caused slight burns to the patient, but which could have been catastrophic, and proposes the use of protocols to prevent such accidents.
Abstract Read Full Article HTMLDOI: 10.29328/journal.ijcar.1001011 Cite this Article
Recent Articles
2020-05-25 Case Report
Khaleel Ahmad Najar* Anka Amin, Mohammad Ommid
Abstract Read Full Article HTMLDOI: 10.29328/journal.ijcar.1001013 Citation
2019-07-09 Research Article
Jens Magunia, Hans-Bernd Hopf and Michael Schutz*
Abstract Read Full Article HTMLDOI: 10.29328/journal.ijcar.1001012 Citation
2019-07-04 Case Report
Domingos Dias Cicarelli*, Fernando Chuluck Silva, Carolina Martins Ricardo, Ana Carolina Makinoo Antunes, Murilo Alexandre Carmona and Maria Jose Carvalho Carmona
Abstract Read Full Article HTMLDOI: 10.29328/journal.ijcar.1001011 Citation
2018-12-19 Research Article
Gangadevi Nandasena and Chrishantha Abeysena*
Abstract Read Full Article HTMLDOI: 10.29328/journal.ijcar.1001010 Citation
2018-11-20 Research Article
Gangadevi Nandasena and Chrishantha Abeysena*
Abstract Read Full Article HTMLDOI: 10.29328/journal.ijcar.1001009 Citation
2018-11-13 Research Article
Christopher Mallard, Brad Withers, Brooke Bauer, Paul A Sloan, Sean Dineen and Annette Rebel*
Abstract Read Full Article HTMLDOI: 10.29328/journal.ijcar.1001008 Citation
2018-10-23 Research Article
Demet Dogan Erol*
Abstract Read Full Article HTMLDOI: 10.29328/journal.ijcar.1001007 Citation
2018-07-25 Research Article
Veronica Atterhem, Magnus Hultin and Tomi Myrberg*
Abstract Read Full Article HTMLDOI: 10.29328/journal.ijcar.1001006 Citation
2018-01-30 Research Article
Nagat S EL-Shmaa*, Mohamed El-Kashlan and Eman Ramadan Salama
Abstract Read Full Article HTMLDOI: 10.29328/journal.ijcar.1001005 Citation